{"title":"Newmar Power Battery Chargers","description":"Created by FishTech Builder","products":[{"product_id":"newmar-pt-7-battery-charger-pt-7","title":"Newmar PT-7 Battery Charger [PT-7]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePT-7 Battery Charger\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eNewmar’s Phase Three Series Battery Chargers employ “Smart” battery charging technology for 12-volt systems aboard marine applications including workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.\u003c\/p\u003e\u003cp\u003eA selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. This model is housed in a rugged stainless-steel case with a durable white powder coat finish, and the internal circuitry is polyurethane-coated for maximum corrosion resistance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e“Smart” circuitry provides three-stage charging – bulk, absorption, float\u003c\/li\u003e\n\u003cli\u003eGel-Cell\/Flooded Lead-acid\/AGM battery type switch selects optimum charge\/float voltages\u003c\/li\u003e\n\u003cli\u003eMultiple isolated output banks; ammeter indicates total output current. (Except PT-7)\u003c\/li\u003e\n\u003cli\u003eThe optional sensor adjusts output voltage based on battery temperature. (Except PT-7)\u003c\/li\u003e\n\u003cli\u003eCurrent limiting prevents damage from overloading\u003c\/li\u003e\n\u003cli\u003eClean well-regulated output can be used as a power supply; can power loads directly without a battery in line\u003c\/li\u003e\n\u003cli\u003eBuilt to last – rugged stainless-steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry\u003c\/li\u003e\n\u003cli\u003eProtection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield\u003c\/li\u003e\n\u003cli\u003eABS-type approval for battery charging and power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput VAC (50-60 Hz.): 88-132 or 176-264 \u003c\/li\u003e\n\u003cli\u003eInput Amps @ Full Load: @ 115 VAC 2, @ 230 VAC 1    \u003c\/li\u003e\n\u003cli\u003eP.F. Rating: \u0026gt;.65 \u003c\/li\u003e\n\u003cli\u003eMax Output Amps: 7\u003c\/li\u003e\n\u003cli\u003eOutput Banks: 2 \u003c\/li\u003e\n\u003cli\u003eBattery Capacity (Amp-Hours): 14-70\u003c\/li\u003e\n\u003cli\u003eOperating Temp. Rating Reference: T-1\u003c\/li\u003e\n\u003cli\u003eCase Size Reference: A-1\u003c\/li\u003e\n\u003cli\u003eCase Size (H x W x D): 10.5 x 5.0 x 2.8 inches (26.7 x 12.7 x 7.1 centimeters)\u003c\/li\u003e\n\u003cli\u003eWeight Lbs.\/Kg: 3.2\/1.5\u003c\/li\u003e\n\u003cli\u003eOptional Temp. Sensor Model: N\/A\u003c\/li\u003e\n\u003cli\u003eRemote Panel Model: N\/A \u003c\/li\u003e\n\u003cli\u003eEqualize Option: No\u003c\/li\u003e\n\u003cli\u003eOutput Indicator Reference: M-1\u003c\/li\u003e\n\u003cli\u003eCompliance Reference: CG, CE    \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTemperature Rating References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature: -10 degrees C to +45 degrees C    \u003c\/li\u003e\n\u003cli\u003eDerate Linearly From 100% @ 0 degrees C to 80% @ -10 degrees C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Output Voltages at Gel\/Flooded Switch Settings (without Temperature Compensation):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGel-Cell: 14.0 VDC Charge @ 50% load and 13.6 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003cli\u003eFlooded\/AGM: 14.2 VDC Charge @ 50% load and 13.4 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompliance References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCG: USCG CFR 183.410 (Ignition protected)\u003c\/li\u003e\n\u003cli\u003eCE: Carries the CE mark\u003c\/li\u003e\n\u003cli\u003eABS: PT Series meet SVR 2009 4-8-3\/5.9, Under 90 meters Rules 2006 4-6-4\/7.19, and HSNC 2007 4-8-3\/5.13\u003c\/li\u003e\n\u003c\/ul\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase.  Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e \u003c!--- cis2:m2lnm5xn ---\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 7a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eCharging Banks: 2\u003c\/li\u003e\n\u003cli\u003ePortable: No\u003c\/li\u003e\n\u003cli\u003eInverter Input Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eInverter Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eOutlet Qty: Hardwire\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 6\"H x 7\"W x 12\"L WT: 3.85 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/102326QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/102326OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e","brand":"Newmar Power","offers":[{"title":"Default Title","offer_id":48599982342393,"sku":"FTD-102326","price":402.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/5174\/4505\/files\/102326XL.jpg?v=1782536895"},{"product_id":"newmar-pt-14w-battery-charger-pt-14w","title":"Newmar PT-14W Battery Charger [PT-14W]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePT-14W Battery Charger\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eNewmar’s Phase Three Series Battery Chargers employ “Smart” battery charging technology for 12-volt systems aboard marine applications including workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.\u003c\/p\u003e\u003cp\u003eA selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. This model is housed in a rugged stainless-steel case with a durable white powder coat finish, and the internal circuitry is polyurethane-coated for maximum corrosion resistance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e“Smart” circuitry provides three-stage charging – bulk, absorption, float\u003c\/li\u003e\n\u003cli\u003eGel-Cell\/Flooded Lead-acid\/AGM battery type switch selects optimum charge\/float voltages\u003c\/li\u003e\n\u003cli\u003eMultiple isolated output banks; ammeter indicates total output current. (Except PT-7)\u003c\/li\u003e\n\u003cli\u003eThe optional sensor adjusts output voltage based on battery temperature. (Except PT-7)\u003c\/li\u003e\n\u003cli\u003eCurrent limiting prevents damage from overloading\u003c\/li\u003e\n\u003cli\u003eClean well-regulated output can be used as a power supply; can power loads directly without a battery in line\u003c\/li\u003e\n\u003cli\u003eBuilt to last – rugged stainless-steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry\u003c\/li\u003e\n\u003cli\u003eProtection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield\u003c\/li\u003e\n\u003cli\u003eABS-type approval for battery charging and power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput VAC (50-60 Hz.): 85-264    \u003c\/li\u003e\n\u003cli\u003eInput Amps @ Full Load: @ 115 VAC: 2.8, @ 230 VAC: 1.4 \u003c\/li\u003e\n\u003cli\u003eP.F. Rating: .93@230V and .98@115V\u003c\/li\u003e\n\u003cli\u003eMax Output Amps: 14\u003c\/li\u003e\n\u003cli\u003eOutput Banks: 3\u003c\/li\u003e\n\u003cli\u003eBattery Capacity (Amp-Hours): 28-140    \u003c\/li\u003e\n\u003cli\u003eOperating Temp. Rating Reference: T-2\u003c\/li\u003e\n\u003cli\u003eCase Size Reference: A-2\u003c\/li\u003e\n\u003cli\u003eCase Size (H x W x D): 11.2A x 7.7 x 4.75A inches (31.8A x 19.6 x 12.1A centimeters) *Note with Dripshield installed A add 1.1” (2.8 cm) to height and .92” (2.3 cm) to depth\u003c\/li\u003e\n\u003cli\u003eWeight Lbs.\/Kg: 8\/4\u003c\/li\u003e\n\u003cli\u003eOptional Temp. Sensor Model: TCS-12\/24    \u003c\/li\u003e\n\u003cli\u003eRemote Panel Model: RP\u003c\/li\u003e\n\u003cli\u003eEqualize Option: Yes\u003c\/li\u003e\n\u003cli\u003eOutput Indicator Reference: M-3\u003c\/li\u003e\n\u003cli\u003eCompliance Reference: CG, CE    \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTemperature Rating References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature: -10 degrees C to +60 degrees C    \u003c\/li\u003e\n\u003cli\u003eDerate Linearly From 100% @ 40 degrees C to 60% @ 60 degrees C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Output Voltages at Gel\/Flooded Switch Settings (without Temperature Compensation):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGel-Cell: 14.0 VDC Charge @ 50% load and 13.6 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003cli\u003eFlooded\/AGM: 14.2 VDC Charge @ 50% load and 13.4 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompliance References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCG: USCG CFR 183.410 (Ignition protected)\u003c\/li\u003e\n\u003cli\u003eCE: Carries the CE mark\u003c\/li\u003e\n\u003cli\u003eABS: PT Series meets SVR 2009 4-8-3\/5.9, Under 90 meters Rules 2006 4-6-4\/7.19, and HSNC 2007 4-8-3\/5.13.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eRemote Panel, model RP, for use with all models except PT-7 and PT-40U (LEDs indicate the charger output stage. Manual re-initialization of a three-stage charge cycle. With 25′ of cable. Panel dimensions: 3″ H x 4.75″ W)\u003c\/li\u003e\u003c\/ul\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase.  Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e \u003c!--- cis2:m2lnm5xn ---\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 14a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eCharging Banks: 3\u003c\/li\u003e\n\u003cli\u003ePortable: No\u003c\/li\u003e\n\u003cli\u003eInverter Input Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eInverter Output Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eOutlet Qty: Hardwire\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 10\"H x 11\"W x 16\"L WT: 9.5 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/102327QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/102327OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e","brand":"Newmar Power","offers":[{"title":"Default Title","offer_id":48599982375161,"sku":"FTD-102327","price":803.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/5174\/4505\/files\/102327XL.jpg?v=1782536895"},{"product_id":"newmar-pt-24-13w-battery-charger-pt-24-13w","title":"Newmar PT-24-13W Battery Charger [PT-24-13W]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePT-24-13W Battery Charger\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e“Smart” marine battery charging technology for 24-volt systems aboard workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.\u003c\/p\u003e\u003cp\u003eA selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. All models are housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e24-volt model\u003c\/li\u003e\n\u003cli\u003e“Smart” circuitry provides three-stage charging – bulk, absorption, float\u003c\/li\u003e\n\u003cli\u003eGel-Cell\/Flooded Lead-acid\/AGM battery type switch selects optimum charge\/float voltages\u003c\/li\u003e\n\u003cli\u003eMultiple isolated output banks; ammeter indicates total output current\u003c\/li\u003e\n\u003cli\u003eThe optional sensor adjusts output voltage based on battery temperature\u003c\/li\u003e\n\u003cli\u003eCurrent limiting prevents damage from overloading\u003c\/li\u003e\n\u003cli\u003eUse as a power supply; can power loads without a battery in line\u003c\/li\u003e\n\u003cli\u003eBuilt to last – rugged stainless steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry\u003c\/li\u003e\n\u003cli\u003eProtection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield\u003c\/li\u003e\n\u003cli\u003eInstall in conjunction with PT-MCU for additional control and monitoring\u003c\/li\u003e\n\u003cli\u003eABS-type approval for battery charging and power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput VAC (50-60 Hz.): 90 – 132, 180 – 264\u003c\/li\u003e\n\u003cli\u003eInput Amps @ Full Load: @ 115 VAC: 6.5, @ 230 VAC: 4 \u003c\/li\u003e\n\u003cli\u003ePower Factor: .7\u003c\/li\u003e\n\u003cli\u003eMax Output Amps: 13\u003c\/li\u003e\n\u003cli\u003eOutput Banks: 3\u003c\/li\u003e\n\u003cli\u003eBattery Capacity (Amp-Hours): 26 – 130\u003c\/li\u003e\n\u003cli\u003eOperating Temp. Rating Reference: T-2\u003c\/li\u003e\n\u003cli\u003eCase Size Reference: A-1\u003c\/li\u003e\n\u003cli\u003eCase Size (H x W x D): 11.2A x 7.7 x 4.75A inches (28.4A x 19.6 x 12.1A centimeters) *Note with Dripshield installed A add 1.1” (2.8 cm) to height and .92” (2.3 cm) to depth\u003c\/li\u003e\n\u003cli\u003eWeight Lbs.\/Kg: 8\/4\u003c\/li\u003e\n\u003cli\u003eOptional Temp. Sensor Model: TCS-12\/24    \u003c\/li\u003e\n\u003cli\u003eRemote Panel Model: RP\u003c\/li\u003e\n\u003cli\u003eCompliance Reference: CG, ABS \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTemperature Rating References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature: -10 degrees C to +60 degrees C    \u003c\/li\u003e\n\u003cli\u003eDerate Linearly From 100% @ 50 degrees C to 60% @ 60 degrees C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Output Voltages at Gel\/Flooded Switch Settings (without Temperature Compensation):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGel-Cell: 28.0 VDC Charge @ 50% load and 27.2 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003cli\u003eFlooded\/AGM: 28.4 VDC Charge @ 50% load and 26.8 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompliance References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUL: UL 1950 (per DNB report)\u003c\/li\u003e\n\u003cli\u003eCG: USCG CFR 183.410 (Ignition protected)\u003c\/li\u003e\n\u003cli\u003eEN: EN 60335-1\u003c\/li\u003e\n\u003cli\u003eCE: Carries the CE mark\u003c\/li\u003e\n\u003cli\u003eABS: PT Series meets SVR 2009 4-8-3\/5.9, Under 90 meters Rules 2006 4-6-4\/7.19, and HSNC 2007 4-8-3\/5.13.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eRemote Panel, model RP, for use with all models except PT-24-20U, PT-24-60, and PT-32-25 (LEDs indicate charger output stage. Manual re-initialization of three-stage charge cycle. With 25′ of cable. Panel dimensions: 3″ H x 4.75″ W)\u003c\/li\u003e\u003c\/ul\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase.  Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e \u003c!--- cis2:m2lnm5xn ---\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 13a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eCharging Banks: 3\u003c\/li\u003e\n\u003cli\u003ePortable: No\u003c\/li\u003e\n\u003cli\u003eInverter Input Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eInverter Output Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eOutlet Qty: Hardwire\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 10\"H x 10\"W x 16\"L WT: 9 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/102328OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e","brand":"Newmar Power","offers":[{"title":"Default Title","offer_id":48599982407929,"sku":"FTD-102328","price":913.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/5174\/4505\/files\/102328XL.jpg?v=1782536896"},{"product_id":"newmar-pt-24-20u-battery-charger-pt-24-20u","title":"Newmar PT-24-20U Battery Charger [PT-24-20U]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePT-24-20U Battery Charge\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e“Smart” marine battery charging technology for 24-volt systems aboard workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.\u003c\/p\u003e\u003cp\u003eA selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. All models are housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e24-volt model\u003c\/li\u003e\n\u003cli\u003e“Smart” circuitry provides three-stage charging – bulk, absorption, float\u003c\/li\u003e\n\u003cli\u003eGel-cell\/Flooded Lead-acid\/AGM battery type switch selects optimum charge\/float voltages\u003c\/li\u003e\n\u003cli\u003eMultiple isolated output banks; ammeter indicates total output current\u003c\/li\u003e\n\u003cli\u003eThe optional sensor adjusts output voltage based on battery temperature\u003c\/li\u003e\n\u003cli\u003eCurrent limiting prevents damage from overloading\u003c\/li\u003e\n\u003cli\u003eUse as a power supply; can power loads without a battery in line\u003c\/li\u003e\n\u003cli\u003eBuilt to last – rugged stainless steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry\u003c\/li\u003e\n\u003cli\u003eProtection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield\u003c\/li\u003e\n\u003cli\u003eInstall in conjunction with PT-MCU for additional control and monitoring\u003c\/li\u003e\n\u003cli\u003eABS-type approval for battery charging and power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput VAC (50-60 Hz.): 85 – 135, 170 – 270\u003c\/li\u003e\n\u003cli\u003eInput Amps @ Full Load: @ 115 VAC: 6.8, @ 230 VAC: 4.3 \u003c\/li\u003e\n\u003cli\u003ePower Factor: .7\u003c\/li\u003e\n\u003cli\u003eMax Output Amps: 20\u003c\/li\u003e\n\u003cli\u003eOutput Banks: 3\u003c\/li\u003e\n\u003cli\u003eBattery Capacity (Amp-Hours): 40– 200\u003c\/li\u003e\n\u003cli\u003eOperating Temp. Rating Reference: T-3\u003c\/li\u003e\n\u003cli\u003eCase Size Reference: A-2\u003c\/li\u003e\n\u003cli\u003eCase Size (H x W x D): 13.85B x 9.5 x 4.8B inches (35.2B x 24.1 x 12.2B centimeters) *Note with Dripshield installed B add .75” (1.9 cm) to height and 1.35” (3.4 cm) to depth\u003c\/li\u003e\n\u003cli\u003eWeight Lbs.\/Kg: 12\/6\u003c\/li\u003e\n\u003cli\u003eOptional Temp. Sensor Model: TCS-12\/24    \u003c\/li\u003e\n\u003cli\u003eRemote Panel Model: NA\u003c\/li\u003e\n\u003cli\u003eCompliance Reference: CG, ABS\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTemperature Rating References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature: -20 degrees C to +60 degrees C    \u003c\/li\u003e\n\u003cli\u003eDerate Linearly From 100% @ 50 degrees C to 60% @ 60 degrees C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Output Voltages at Gel\/Flooded Switch Settings (without Temperature Compensation):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGel-Cell: 28.0 VDC Charge @ 50% load and 27.2 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003cli\u003eFlooded\/AGM: 28.4 VDC Charge @ 50% load and 26.8 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompliance References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUL: UL 1950 (per DNB report)\u003c\/li\u003e\n\u003cli\u003eCG: USCG CFR 183.410 (Ignition protected)\u003c\/li\u003e\n\u003cli\u003eEN: EN 60335-1\u003c\/li\u003e\n\u003cli\u003eCE: Carries the CE mark\u003c\/li\u003e\n\u003cli\u003eABS: PT Series meets SVR 2009 4-8-3\/5.9, Under 90 meters Rules 2006 4-6-4\/7.19, and HSNC 2007 4-8-3\/5.13.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase.  Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e \u003c!--- cis2:m2lnm5xn ---\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 20a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eCharging Banks: 3\u003c\/li\u003e\n\u003cli\u003ePortable: No\u003c\/li\u003e\n\u003cli\u003eInverter Input Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eInverter Output Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eOutlet Qty: Hardwire\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 11\"H x 15\"W x 20\"L WT: 14.3 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/102329QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/102329OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e","brand":"Newmar Power","offers":[{"title":"Default Title","offer_id":48599982473465,"sku":"FTD-102329","price":1411.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/5174\/4505\/files\/102329XL.jpg?v=1782536896"},{"product_id":"newmar-pt-24-45u-battery-charger-pt-24-45u","title":"Newmar PT-24-45U Battery Charger [PT-24-45U]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePT-24-45U Battery Charger\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e“Smart” marine battery charging technology for 24-volt systems aboard workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.\u003c\/p\u003e\u003cp\u003eA selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. All models are housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e24-volt model\u003c\/li\u003e\n\u003cli\u003e“Smart” circuitry provides three-stage charging – bulk, absorption, float\u003c\/li\u003e\n\u003cli\u003eGel-Cell\/Flooded Lead-acid\/AGM battery type switch selects optimum charge\/float voltages\u003c\/li\u003e\n\u003cli\u003eMultiple isolated output banks; ammeter indicates total output current\u003c\/li\u003e\n\u003cli\u003eThe optional sensor adjusts output voltage based on battery temperature\u003c\/li\u003e\n\u003cli\u003eCurrent limiting prevents damage from overloading\u003c\/li\u003e\n\u003cli\u003eUse as a power supply; can power loads without a battery in line\u003c\/li\u003e\n\u003cli\u003eBuilt to last – rugged stainless steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry\u003c\/li\u003e\n\u003cli\u003eProtection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield\u003c\/li\u003e\n\u003cli\u003eInstall in conjunction with PT-MCU for additional control and monitoring\u003c\/li\u003e\n\u003cli\u003eABS-type approval for battery charging and power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput VAC (50-60 Hz.): 90 – 264\u003c\/li\u003e\n\u003cli\u003eInput Amps @ Full Load: @ 115 VAC: 12, @ 230 VAC: 7 \u003c\/li\u003e\n\u003cli\u003ePower Factor: .98@115V and .95@230V\u003c\/li\u003e\n\u003cli\u003eMax Output Amps: 45\u003c\/li\u003e\n\u003cli\u003eOutput Banks: 3\u003c\/li\u003e\n\u003cli\u003eBattery Capacity (Amp-Hours): 90 – 450\u003c\/li\u003e\n\u003cli\u003eOperating Temp. Rating Reference: T-5\u003c\/li\u003e\n\u003cli\u003eCase Size Reference: A-4\u003c\/li\u003e\n\u003cli\u003eCase Size (H x W x D): 14.8B x 9.6 x 5.6D inches (37.6D x 24.4 x 14.2D centimeters) *Note with Dripshield installed D add 1” (2.54 cm) to height and .5” (1.2 cm) to depth\u003c\/li\u003e\n\u003cli\u003eWeight Lbs.\/Kg: 12\/6\u003c\/li\u003e\n\u003cli\u003eOptional Temp. Sensor Model: TCS-12\/24    \u003c\/li\u003e\n\u003cli\u003eRemote Panel Model: RP\u003c\/li\u003e\n\u003cli\u003eCompliance Reference: EN, CE, ABS\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTemperature Rating References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature: -20 degrees C to +70 degrees C    \u003c\/li\u003e\n\u003cli\u003eDerate Linearly From 100% @ 50 degrees C to 50% @ 70 degrees C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Output Voltages at Gel\/Flooded Switch Settings (without Temperature Compensation):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGel-Cell: 28.0 VDC Charge @ 50% load and 27.2 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003cli\u003eFlooded\/AGM: 28.4 VDC Charge @ 50% load and 26.8 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompliance References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUL: UL 1950 (per DNB report)\u003c\/li\u003e\n\u003cli\u003eCG: USCG CFR 183.410 (Ignition protected)\u003c\/li\u003e\n\u003cli\u003eEN: EN 60335-1\u003c\/li\u003e\n\u003cli\u003eCE: Carries the CE mark\u003c\/li\u003e\n\u003cli\u003eABS: PT Series meets SVR 2009 4-8-3\/5.9, Under 90 meters Rules 2006 4-6-4\/7.19, and HSNC 2007 4-8-3\/5.13.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eRemote Panel, model RP, for use with all models except PT-24-20U, PT-24-60, and PT-32-25 (LEDs indicate charger output stage. Manual re-initialization of three-stage charge cycle. With 25′ of cable. Panel dimensions: 3″ H x 4.75″ W)\u003c\/li\u003e\u003c\/ul\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase.  Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e \u003c!--- cis2:m2lnm5xn ---\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 45a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eCharging Banks: 3\u003c\/li\u003e\n\u003cli\u003ePortable: No\u003c\/li\u003e\n\u003cli\u003eInverter Input Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eInverter Output Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eOutlet Qty: Hardwire\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 10\"H x 14\"W x 20\"L WT: 18 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/102330QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/102330OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e","brand":"Newmar Power","offers":[{"title":"Default Title","offer_id":48599982506233,"sku":"FTD-102330","price":2309.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/5174\/4505\/files\/102330XL.jpg?v=1782536896"},{"product_id":"newmar-pt-24-60w-battery-charger-pt-24-60w","title":"Newmar PT-24-60W Battery Charger [PT-24-60W]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePT-24-60W Battery Charger\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e“Smart” marine battery charging technology for 24V systems aboard workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.\u003c\/p\u003e\u003cp\u003eA selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. All models are housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e24V model\u003c\/li\u003e\n\u003cli\u003e“Smart” circuitry provides three-stage charging – bulk, absorption, float\u003c\/li\u003e\n\u003cli\u003eGel-cell\/Flooded Lead-acid\/AGM battery type switch selects optimum charge\/float voltages\u003c\/li\u003e\n\u003cli\u003eMultiple isolated output banks; ammeter indicates total output current\u003c\/li\u003e\n\u003cli\u003eThe optional sensor adjusts output voltage based on battery temperature\u003c\/li\u003e\n\u003cli\u003eCurrent limiting prevents damage from overloading\u003c\/li\u003e\n\u003cli\u003eUse as a power supply; can power loads without a battery in line\u003c\/li\u003e\n\u003cli\u003eBuilt to last – rugged stainless steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry\u003c\/li\u003e\n\u003cli\u003eProtection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield\u003c\/li\u003e\n\u003cli\u003eInstall in conjunction with PT-MCU for additional control and monitoring\u003c\/li\u003e\n\u003cli\u003eABS type approval for battery charging and power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput VAC (50-60 Hz.): 207-253\u003c\/li\u003e\n\u003cli\u003eInput Amps @ Full Load: @ 115 VAC: NA, @ 230 VAC: 13\u003c\/li\u003e\n\u003cli\u003ePower Factor: .7\u003c\/li\u003e\n\u003cli\u003eMax Output Amps: 60\u003c\/li\u003e\n\u003cli\u003eOutput Banks: 3\u003c\/li\u003e\n\u003cli\u003eBattery Capacity (Amp-Hours): 120-600    \u003c\/li\u003e\n\u003cli\u003eOperating Temp. Rating Reference: T-4\u003c\/li\u003e\n\u003cli\u003eCase Size Reference: A-5\u003c\/li\u003e\n\u003cli\u003eCase Size (H x W x D): 17.5E x 12 x 7.2E inches (44.5E x 30.5 x 18.3E centimeters) *Note with Dripshield installed E add 2” (5.08 cm) to height and 1” (2.54 cm) to depth\u003c\/li\u003e\n\u003cli\u003eWeight Lbs.\/Kg: 24.1\/11\u003c\/li\u003e\n\u003cli\u003eOptional Temp. Sensor Model: TP    \u003c\/li\u003e\n\u003cli\u003eRemote Panel Model: N\/A\u003c\/li\u003e\n\u003cli\u003eCompliance Reference: EN, CE, ABS\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTemperature Rating References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature: -20 degrees C to +50 degrees C    \u003c\/li\u003e\n\u003cli\u003eDerate Linearly From Full output\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Output Voltages at Gel\/Flooded Switch Settings (without Temperature Compensation):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGel-Cell: 28.0 VDC Charge @ 50% load and 27.2 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003cli\u003eFlooded\/AGM: 28.4 VDC Charge @ 50% load and 26.8 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompliance References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUL: UL 1950 (per DNB report)\u003c\/li\u003e\n\u003cli\u003eCG: USCG CFR 183.410 (Ignition protected)\u003c\/li\u003e\n\u003cli\u003eEN: EN 60335-1\u003c\/li\u003e\n\u003cli\u003eCE: Carries the CE mark\u003c\/li\u003e\n\u003cli\u003eABS: PT Series meets SVR 2009 4-8-3\/5.9, Under 90 meters Rules 2006 4-6-4\/7.19, and HSNC 2007 4-8-3\/5.13.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase.  Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e \u003c!--- cis2:m2lnm5xn ---\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/102331QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/102331OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e","brand":"Newmar Power","offers":[{"title":"Default Title","offer_id":48599982539001,"sku":"FTD-102331","price":3381.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/5174\/4505\/files\/102331XL.jpg?v=1782536897"},{"product_id":"newmar-pt-24-8w-battery-charger-pt-24-8w","title":"Newmar PT-24-8W Battery Charger [PT-24-8W]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePT-24-8W Battery Charger\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e“Smart” marine battery charging technology for 24-volt systems aboard workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.\u003c\/p\u003e\u003cp\u003eA selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. All models are housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e24-volt model\u003c\/li\u003e\n\u003cli\u003e“Smart” circuitry provides three-stage charging – bulk, absorption, float\u003c\/li\u003e\n\u003cli\u003eGel-Cell\/Flooded Lead-acid\/AGM battery type switch selects optimum charge\/float voltages\u003c\/li\u003e\n\u003cli\u003eMultiple isolated output banks; ammeter indicates total output current\u003c\/li\u003e\n\u003cli\u003eThe optional sensor adjusts output voltage based on battery temperature\u003c\/li\u003e\n\u003cli\u003eCurrent limiting prevents damage from overloading\u003c\/li\u003e\n\u003cli\u003eUse as a power supply; can power loads without a battery in line\u003c\/li\u003e\n\u003cli\u003eBuilt to last – rugged stainless steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry\u003c\/li\u003e\n\u003cli\u003eProtection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield\u003c\/li\u003e\n\u003cli\u003eInstall in conjunction with PT-MCU for additional control and monitoring\u003c\/li\u003e\n\u003cli\u003eABS-type approval for battery charging and power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput VAC (50-60 Hz.): 85 – 264\u003c\/li\u003e\n\u003cli\u003eInput Amps @ Full Load: @ 115 VAC: 2.8, @ 230 VAC: 1.4\u003c\/li\u003e\n\u003cli\u003ePower Factor: .98@115V and .93@230V\u003c\/li\u003e\n\u003cli\u003eMax Output Amps: 8\u003c\/li\u003e\n\u003cli\u003eOutput Banks: 3\u003c\/li\u003e\n\u003cli\u003eBattery Capacity (Amp-Hours): 16 – 80\u003c\/li\u003e\n\u003cli\u003eOperating Temp. Rating Reference: T-1\u003c\/li\u003e\n\u003cli\u003eCase Size Reference: A-1\u003c\/li\u003e\n\u003cli\u003eCase Size (H x W x D): 11.2A x 7.7 x 4.75A inches (28.4A x 19.6 x 12.1A centimeters) *Note with Dripshield installed A add 1.1” (2.8 cm) to height and .92” (2.3 cm) to depth\u003c\/li\u003e\n\u003cli\u003eWeight Lbs.\/Kg: 8\/4\u003c\/li\u003e\n\u003cli\u003eOptional Temp. Sensor Model: TCS-12\/24        \u003c\/li\u003e\n\u003cli\u003eRemote Panel Model: RP\u003c\/li\u003e\n\u003cli\u003eCompliance Reference: CG, CE, ABS\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTemperature Rating References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature: -10 degrees C to +60 degrees C\u003c\/li\u003e\n\u003cli\u003eDerate Linearly From 100% @ 40 degrees C to 60% @ 60 degrees C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Output Voltages at Gel\/Flooded Switch Settings (without Temperature Compensation):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGel-Cell: 28.0 VDC Charge @ 50% load and 27.2 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003cli\u003eFlooded\/AGM: 28.4 VDC Charge @ 50% load and 26.8 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompliance References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUL: UL 1950 (per DNB report)\u003c\/li\u003e\n\u003cli\u003eCG: USCG CFR 183.410 (Ignition protected)\u003c\/li\u003e\n\u003cli\u003eEN: EN 60335-1\u003c\/li\u003e\n\u003cli\u003eCE: Carries the CE mark\u003c\/li\u003e\n\u003cli\u003eABS: PT Series meets SVR 2009 4-8-3\/5.9, Under 90 meters Rules 2006 4-6-4\/7.19, and HSNC 2007 4-8-3\/5.13.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eRemote Panel, model RP, for use with all models except PT-24-20U, PT-24-60, and PT-32-25 (LEDs indicate charger output stage. Manual re-initialization of three-stage charge cycle. With 25′ of cable. Panel dimensions: 3″ H x 4.75″ W)\u003c\/li\u003e\u003c\/ul\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase.  Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e \u003c!--- cis2:m2lnm5xn ---\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 8a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eCharging Banks: 3\u003c\/li\u003e\n\u003cli\u003ePortable: No\u003c\/li\u003e\n\u003cli\u003eInverter Input Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eInverter Output Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eOutlet Qty: Hardwire\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 10\"H x 10\"W x 16\"L WT: 8.3 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/102332QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/102332OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e","brand":"Newmar Power","offers":[{"title":"Default Title","offer_id":48599982571769,"sku":"FTD-102332","price":1017.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/5174\/4505\/files\/102332XL.jpg?v=1782536897"},{"product_id":"newmar-pt-24-95u-battery-charger-pt-24-95u","title":"Newmar PT-24-95U Battery Charger [PT-24-95U]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePT-24-95U Battery Charger\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e“Smart” marine battery charging technology for 24-volt systems aboard workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.\u003c\/p\u003e\u003cp\u003eA selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. All models are housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e24-volt model\u003c\/li\u003e\n\u003cli\u003e“Smart” circuitry provides three-stage charging – bulk, absorption, float\u003c\/li\u003e\n\u003cli\u003eGel-Cell\/Flooded Lead-acid\/AGM battery type switch selects optimum charge\/float voltages\u003c\/li\u003e\n\u003cli\u003eMultiple isolated output banks; ammeter indicates total output current\u003c\/li\u003e\n\u003cli\u003eThe optional sensor adjusts output voltage based on battery temperature\u003c\/li\u003e\n\u003cli\u003eCurrent limiting prevents damage from overloading\u003c\/li\u003e\n\u003cli\u003eUse as a power supply; can power loads without a battery in line\u003c\/li\u003e\n\u003cli\u003eBuilt to last – rugged stainless steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry\u003c\/li\u003e\n\u003cli\u003eProtection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield\u003c\/li\u003e\n\u003cli\u003eInstall in conjunction with PT-MCU for additional control and monitoring\u003c\/li\u003e\n\u003cli\u003eABS-type approval for battery charging and power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput VAC (50-60 Hz.): 90-264\u003c\/li\u003e\n\u003cli\u003eInput Amps @ Full Load: @ 115 VAC: 26, @ 230 VAC: 14\u003c\/li\u003e\n\u003cli\u003ePower Factor: .98@115V and .95@230V\u003c\/li\u003e\n\u003cli\u003eMax Output Amps: 95\u003c\/li\u003e\n\u003cli\u003eOutput Banks: 3\u003c\/li\u003e\n\u003cli\u003eBattery Capacity (Amp-Hours): 180 – 950\u003c\/li\u003e\n\u003cli\u003eOperating Temp. Rating Reference: T-5\u003c\/li\u003e\n\u003cli\u003eCase Size Reference: A-5\u003c\/li\u003e\n\u003cli\u003eCase Size (H x W x D): 17.5E x 12 x 7.2E inches (44.5E x 30.5 x 18.3E centimeters) *Note with Dripshield installed E add 2” (5.08 cm) to height and 1” (2.54 cm) to depth\u003c\/li\u003e\n\u003cli\u003eWeight Lbs.\/Kg: 24.5\/11\u003c\/li\u003e\n\u003cli\u003eOptional Temp. Sensor Model: TCS-12\/24            \u003c\/li\u003e\n\u003cli\u003eRemote Panel Model: RP\u003c\/li\u003e\n\u003cli\u003eCompliance Reference: EN, CE, ABS\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTemperature Rating References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature: -20 degrees C to +70 degrees C\u003c\/li\u003e\n\u003cli\u003eDerate Linearly From 100% @ 50 degrees C to 50% @ 70 degrees C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Output Voltages at Gel\/Flooded Switch Settings (without Temperature Compensation):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGel-Cell: 28.0 VDC Charge @ 50% load and 27.2 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003cli\u003eFlooded\/AGM: 28.4 VDC Charge @ 50% load and 26.8 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompliance References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUL: UL 1950 (per DNB report)\u003c\/li\u003e\n\u003cli\u003eCG: USCG CFR 183.410 (Ignition protected)\u003c\/li\u003e\n\u003cli\u003eEN: EN 60335-1\u003c\/li\u003e\n\u003cli\u003eCE: Carries the CE mark\u003c\/li\u003e\n\u003cli\u003eABS: PT Series meets SVR 2009 4-8-3\/5.9, Under 90 meters Rules 2006 4-6-4\/7.19, and HSNC 2007 4-8-3\/5.13.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eRemote Panel, model RP, for use with all models except PT-24-20U, PT-24-60, and PT-32-25 (LEDs indicate charger output stage. Manual re-initialization of three-stage charge cycle. With 25′ of cable. Panel dimensions: 3″ H x 4.75″ W)\u003c\/li\u003e\u003c\/ul\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase.  Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e \u003c!--- cis2:m2lnm5xn ---\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 95a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eCharging Banks: 3\u003c\/li\u003e\n\u003cli\u003ePortable: No\u003c\/li\u003e\n\u003cli\u003eInverter Input Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eInverter Output Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eOutlet Qty: Hardwire\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 12\"H x 17\"W x 25\"L WT: 31.5 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/102333QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/102333OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e","brand":"Newmar Power","offers":[{"title":"Default Title","offer_id":48599982604537,"sku":"FTD-102333","price":3613.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/5174\/4505\/files\/102333XL.jpg?v=1782536897"},{"product_id":"newmar-pt-25w-battery-charger-pt-25w","title":"Newmar PT-25W Battery Charger [PT-25W]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePT-25W Battery Charger\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eNewmar’s Phase Three Series Battery Chargers employ “Smart” battery charging technology for 12-volt systems aboard marine applications including workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.\u003c\/p\u003e\u003cp\u003eA selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. This model is housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e12-volt model\u003c\/li\u003e\n\u003cli\u003e“Smart” circuitry provides three-stage charging – bulk, absorption, and float\u003c\/li\u003e\n\u003cli\u003eGel-Cell\/Flooded Lead-acid\/AGM battery type switch selects optimum charge\/float voltages\u003c\/li\u003e\n\u003cli\u003eMultiple isolated output banks; ammeter indicates total output current. (Except PT-7)\u003c\/li\u003e\n\u003cli\u003eThe optional sensor adjusts the output voltage based on battery temperature. (Except PT-7)\u003c\/li\u003e\n\u003cli\u003eCurrent limitations prevent damage from overloading\u003c\/li\u003e\n\u003cli\u003eClean well-regulated output can be used as a power supply; can power loads directly without a battery in line\u003c\/li\u003e\n\u003cli\u003eBuilt to last – rugged stainless steel case with a durable white powder coat finish, an optional drip shield, and marinized internal circuitry\u003c\/li\u003e\n\u003cli\u003eProtection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield\u003c\/li\u003e\n\u003cli\u003eABS-type approval for battery charging and power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput VAC (50-60 Hz.): 90-132 or 180-264\u003c\/li\u003e\n\u003cli\u003eInput Amps @ Full Load: @ 115 VAC: 6.5, @ 230 VAC: 4\u003c\/li\u003e\n\u003cli\u003ePower Factor: .7\u003c\/li\u003e\n\u003cli\u003eMax Output Amps: 25\u003c\/li\u003e\n\u003cli\u003eOutput Banks: 3\u003c\/li\u003e\n\u003cli\u003eBattery Capacity (Amp-Hours): 50-250\u003c\/li\u003e\n\u003cli\u003eOperating Temp. Rating Reference: T-4\u003c\/li\u003e\n\u003cli\u003eCase Size Reference: A-2\u003c\/li\u003e\n\u003cli\u003eCase Size (H x W x D): 11.2A x 7.7 x 4.75A inches (31.8A x 19.6 x 12.1A centimeters) *Note with Dripshield installed A add 1.1” (2.8 cm) to height and .92” (2.3 cm) to depth\u003c\/li\u003e\n\u003cli\u003eWeight Lbs.\/Kg: 8.2\/4\u003c\/li\u003e\n\u003cli\u003eOptional Temp. Sensor Model: TCS-12\/24                \u003c\/li\u003e\n\u003cli\u003eRemote Panel Model: RP\u003c\/li\u003e\n\u003cli\u003eEqualize Option: Yes\u003c\/li\u003e\n\u003cli\u003eOutput Indicator Reference: M-3\u003c\/li\u003e\n\u003cli\u003eCompliance Reference: CG\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTemperature Rating References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature: -20 degrees C to +60 degrees C\u003c\/li\u003e\n\u003cli\u003eDerate Linearly From 100% @ 50 degrees C to 60% @ 60 degrees C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Output Voltages at Gel\/Flooded Switch Settings (without Temperature Compensation):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGel-Cell: 14.0 VDC Charge @ 50% load and 13.6 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003cli\u003eFlooded\/AGM: 14.2 VDC Charge @ 50% load and 13.4 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompliance References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCG: USCG CFR 183.410 (Ignition protected)\u003c\/li\u003e\n\u003cli\u003eCE: Carries the CE mark\u003c\/li\u003e\n\u003cli\u003eABS: PT Series meets SVR 2009 4-8-3\/5.9, Under 90 meters Rules 2006 4-6-4\/7.19, and HSNC 2007 4-8-3\/5.13.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemote Panel, model RP, for use with all models except PT-7 and PT-40U (LEDs indicate charger output stage. Manual re-initialization of three-stage charge cycle. With 25′ of cable. Panel dimensions: 3″ H x 4.75″ W)\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation Sensor, Model TCS 12\/24, for use with all models except PT 7 (-5 mV per cell degrees C, 25′ cable (40’cable optional)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase.  Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e \u003c!--- cis2:m2lnm5xn ---\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 25a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eCharging Banks: 3\u003c\/li\u003e\n\u003cli\u003ePortable: No\u003c\/li\u003e\n\u003cli\u003eInverter Input Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eInverter Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eOutlet Qty: Hardwire\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 10\"H x 10\"W x 16\"L WT: 9.5 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/102334OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e","brand":"Newmar Power","offers":[{"title":"Default Title","offer_id":48599982637305,"sku":"FTD-102334","price":904.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/5174\/4505\/files\/102334XL.jpg?v=1782536897"},{"product_id":"newmar-pt-40u-battery-charger-pt-40u","title":"Newmar PT-40U Battery Charger [PT-40U]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePT-40U Battery Charger\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eNewmar’s Phase Three Series Battery Chargers employ “Smart” battery charging technology for 12-volt systems aboard marine applications including workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.\u003c\/p\u003e\u003cp\u003eA selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. This model is housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e12-volt model\u003c\/li\u003e\n\u003cli\u003e“Smart” circuitry provides three-stage charging – bulk, absorption, and float\u003c\/li\u003e\n\u003cli\u003eGel-Cell\/Flooded Lead-acid\/AGM battery type switch selects optimum charge\/float voltages\u003c\/li\u003e\n\u003cli\u003eMultiple isolated output banks; ammeter indicates total output current. (Except PT-7)\u003c\/li\u003e\n\u003cli\u003eThe optional sensor adjusts the output voltage based on battery temperature. (Except PT-7)\u003c\/li\u003e\n\u003cli\u003eCurrent limitations prevent damage from overloading\u003c\/li\u003e\n\u003cli\u003eClean well-regulated output can be used as a power supply; can power loads directly without a battery in line\u003c\/li\u003e\n\u003cli\u003eBuilt to last – rugged stainless steel case with a durable white powder coat finish, an optional drip shield, and marinized internal circuitry\u003c\/li\u003e\n\u003cli\u003eProtection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield\u003c\/li\u003e\n\u003cli\u003eABS-type approval for battery charging and power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput VAC (50-60 Hz.): 90-264\u003c\/li\u003e\n\u003cli\u003eInput Amps @ Full Load: @ 115 VAC: 6.8, @ 230 VAC: 3.4\u003c\/li\u003e\n\u003cli\u003ePower Factor: .98 @ 115V and .95 @ 230V\u003c\/li\u003e\n\u003cli\u003eMax Output Amps: 40\u003c\/li\u003e\n\u003cli\u003eOutput Banks: 3\u003c\/li\u003e\n\u003cli\u003eBattery Capacity (Amp-Hours): 80-400    \u003c\/li\u003e\n\u003cli\u003eOperating Temp. Rating Reference: T-5\u003c\/li\u003e\n\u003cli\u003eCase Size Reference: A-3\u003c\/li\u003e\n\u003cli\u003eCase Size (H x W x D): 13.85B x 9.5 x 4.8B inches (35.2B x 24.1 x 12.2B centimeters) *Note with Dripshield installed B add .75” (1.9 cm) to height and 1.35” (3.4 cm) to depth\u003c\/li\u003e\n\u003cli\u003eWeight Lbs.\/Kg: 11\/6\u003c\/li\u003e\n\u003cli\u003eOptional Temp. Sensor Model: TCS-12\/24                \u003c\/li\u003e\n\u003cli\u003eRemote Panel Model: EVM-12-2    \u003c\/li\u003e\n\u003cli\u003eEqualize Option: No\u003c\/li\u003e\n\u003cli\u003eOutput Indicator Reference: M-3\u003c\/li\u003e\n\u003cli\u003eCompliance Reference: CG\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTemperature Rating References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature: -20 degrees C to +70 degrees C\u003c\/li\u003e\n\u003cli\u003eDerate Linearly From 100% @ 50 degrees C to 50% @ 70 degrees C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Output Voltages at Gel\/Flooded Switch Settings (without Temperature Compensation):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGel-Cell: 14.0 VDC Charge @ 50% load and 13.6 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003cli\u003eFlooded\/AGM: 14.2 VDC Charge @ 50% load and 13.4 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompliance References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCG: USCG CFR 183.410 (Ignition protected)\u003c\/li\u003e\n\u003cli\u003eCE: Carries the CE mark\u003c\/li\u003e\n\u003cli\u003eABS: PT Series meets SVR 2009 4-8-3\/5.9, Under 90 meters Rules 2006 4-6-4\/7.19, and HSNC 2007 4-8-3\/5.13.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemote Panel, model EVM-12-2, for us with model PT-40 only (Enables monitoring of when the battery charger is “on” and the batteries’ state of readiness, at a glance of two (2) battery banks only)\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation Sensor, Model TCS 12\/24, for use with all models except PT 7 (-5 mV per cell degrees C, 25′ cable (40’cable optional)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase.  Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e \u003c!--- cis2:m2lnm5xn ---\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 40a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eCharging Banks: 3\u003c\/li\u003e\n\u003cli\u003ePortable: No\u003c\/li\u003e\n\u003cli\u003eInverter Input Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eInverter Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eOutlet Qty: Hardwire\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 11\"H x 15\"W x 20\"L WT: 14.7 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/102335QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/102335OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e","brand":"Newmar Power","offers":[{"title":"Default Title","offer_id":48599982670073,"sku":"FTD-102335","price":1462.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/5174\/4505\/files\/102335XL.jpg?v=1782536897"},{"product_id":"newmar-pt-80-battery-charger-pt-80","title":"Newmar PT-80 Battery Charger [PT-80]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePT-80 Battery Charger\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eNewmar’s Phase Three Series Battery Chargers employ “Smart” battery charging technology for 12-volt systems aboard marine applications including workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.\u003c\/p\u003e\u003cp\u003eA selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. This model is housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e12-volt model\u003c\/li\u003e\n\u003cli\u003e“Smart” circuitry provides three-stage charging – bulk, absorption, and float\u003c\/li\u003e\n\u003cli\u003eGel-Cell\/Flooded Lead-acid\/AGM battery type switch selects optimum charge\/float voltages\u003c\/li\u003e\n\u003cli\u003eMultiple isolated output banks; ammeter indicates total output current. (Except PT-7)\u003c\/li\u003e\n\u003cli\u003eThe optional sensor adjusts the output voltage based on battery temperature. (Except PT-7)\u003c\/li\u003e\n\u003cli\u003eCurrent limitations prevent damage from overloading\u003c\/li\u003e\n\u003cli\u003eClean well-regulated output can be used as a power supply; can power loads directly without a battery in line\u003c\/li\u003e\n\u003cli\u003eBuilt to last – rugged stainless steel case with a durable white powder coat finish, an optional drip shield, and marinized internal circuitry\u003c\/li\u003e\n\u003cli\u003eProtection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield\u003c\/li\u003e\n\u003cli\u003eABS-type approval for battery charging and power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput VAC (50-60 Hz.): 90-264\u003c\/li\u003e\n\u003cli\u003eInput Amps @ Full Load: @ 115 VAC: 12, @ 230 VAC: 7\u003c\/li\u003e\n\u003cli\u003ePower Factor: .95@230V or .98@115V\u003c\/li\u003e\n\u003cli\u003eMax Output Amps: 80\u003c\/li\u003e\n\u003cli\u003eOutput Banks: 3\u003c\/li\u003e\n\u003cli\u003eBattery Capacity (Amp-Hours): 160-800\u003c\/li\u003e\n\u003cli\u003eOperating Temp. Rating Reference: T-7\u003c\/li\u003e\n\u003cli\u003eCase Size Reference: A-5\u003c\/li\u003e\n\u003cli\u003eCase Size (H x W x D): 16.8C x 9.6 x 6.1C inches (42.7C x 24.4 x 15.5C centimeters) *Note with Dripshield installed C add 1” (2.54 cm) to height and .5” (1.27 cm) to depth\u003c\/li\u003e\n\u003cli\u003eWeight Lbs.\/Kg: 15.2\/7\u003c\/li\u003e\n\u003cli\u003eOptional Temp. Sensor Model: TCS-12\/24                \u003c\/li\u003e\n\u003cli\u003eRemote Panel Model: RP\u003c\/li\u003e\n\u003cli\u003eEqualize Option: Yes\u003c\/li\u003e\n\u003cli\u003eOutput Indicator Reference: M-3\u003c\/li\u003e\n\u003cli\u003eCompliance Reference: CE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTemperature Rating References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature: -10 degrees C to +60 degrees C\u003c\/li\u003e\n\u003cli\u003eDerate Linearly From 100% @ 50 degrees C to 80% @ 60 degrees C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Output Voltages at Gel\/Flooded Switch Settings (without Temperature Compensation):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGel-Cell: 14.0 VDC Charge @ 50% load and 13.6 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003cli\u003eFlooded\/AGM: 14.2 VDC Charge @ 50% load and 13.4 VDC Float @ .5 amp load\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompliance References:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCG: USCG CFR 183.410 (Ignition protected)\u003c\/li\u003e\n\u003cli\u003eCE: Carries the CE mark\u003c\/li\u003e\n\u003cli\u003eABS: PT Series meet SVR 2009 4-8-3\/5.9, Under 90 meters Rules 2006 4-6-4\/7.19, and HSNC 2007 4-8-3\/5.13\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemote Panel, model RP, for use with all models except PT-7 and PT-40U (LEDs indicate charger output stage. Manual re-initialization of three-stage charge cycle. With 25′ of cable. Panel dimensions: 3″ H x 4.75″ W)\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation Sensor, Model TCS 12\/24, for use with all models except PT 7 (-5 mV per cell degrees C, 25′ cable (40’cable optional)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase.  Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e \u003c!--- cis2:m2lnm5xn ---\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 80a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eCharging Banks: 3\u003c\/li\u003e\n\u003cli\u003ePortable: No\u003c\/li\u003e\n\u003cli\u003eInverter Input Voltage: 115\/230v\u003c\/li\u003e\n\u003cli\u003eInverter Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eOutlet Qty: Hardwire\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 11\"H x 15\"W x 20\"L WT: 18 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/102336QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/102336OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e","brand":"Newmar Power","offers":[{"title":"Default Title","offer_id":48599982702841,"sku":"FTD-102336","price":2568.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/5174\/4505\/files\/102336XL.jpg?v=1782536898"}],"url":"https:\/\/www.fishtechdirect.com\/collections\/newmar-power-battery-chargers.oembed","provider":"Fish Tech Direct","version":"1.0","type":"link"}